Centrifugal Pump Head and Power Calculation for an Overhead Tank

Choosing a pump means answering two questions: how much water per second (discharge) and against how much resistance (head). Too small a pump never fills the tank; too large a pump wastes power and may run far from its best efficiency point. This article walks through a complete calculation for a typical building setup, a centrifugal pump lifting water from an underground sump to an overhead tank, and then checks suction conditions with NPSH.

What Makes Up Total Head

Head is energy per unit weight of liquid, expressed in metres. The pump must supply enough head to overcome everything between the sump surface and the tank inlet.

ComponentMeaningHow to find it
Static suction liftHeight from sump water level up to pump centrelineMeasure on site
Static delivery headHeight from pump centreline to the outlet in the tankMeasure on site
Major (friction) lossFriction along straight pipeDarcy-Weisbach equation
Minor lossesFoot valve, bends, tees, valves, entry and exitSum of K times velocity head
Total head      H = H_static + h_f + h_minor
Velocity        V = Q / A
Velocity head   V^2 / (2g)
Major loss      h_f = f * (L / D) * V^2 / (2g)        (f = Darcy friction factor)
Minor loss      h_m = (sum of K) * V^2 / (2g)
Hydraulic power P_h = rho * g * Q * H
Shaft power     P_s = P_h / eta_pump
Motor input     P_in = P_s / eta_motor

Worked Example: Sump to Overhead Tank

Data: required flow 1.5 L/s (5.4 m^3/h), suction lift 3 m, delivery height 15 m above the pump, pipe inside diameter 40 mm, total pipe length 30 m, Darcy friction factor 0.02, sum of minor loss coefficients 5 (including the foot valve, elbows, a gate valve and the exit). Pump efficiency 60 percent, motor efficiency 85 percent.

Step 1: Velocity and velocity head

A = pi/4 * 0.04^2 = 1.2566e-3 m^2
V = 0.0015 / 1.2566e-3 = 1.194 m/s
V^2 / 2g = 1.194^2 / 19.62 = 0.0726 m

Step 2: Losses

h_f = 0.02 * (30 / 0.04) * 0.0726 = 15 * 0.0726 = 1.09 m
h_m = 5 * 0.0726 = 0.36 m

Step 3: Total head

H = (3 + 15) + 1.09 + 0.36 = 19.45 m  (design for about 20 m)

Step 4: Power

P_h  = 1000 * 9.81 * 0.0015 * 19.45 = 286 W
P_s  = 286 / 0.60 = 477 W
P_in = 477 / 0.85 = 561 W

A 0.75 kW (1 HP) pump set covers this duty with a reasonable margin. When you look at a catalogue, pick a model whose head-discharge curve passes through about 20 m at 5.4 m^3/h, preferably near its best efficiency point.

Checking Suction with NPSH

If pressure at the pump inlet falls below the vapour pressure of water, bubbles form and collapse violently on the impeller. This is cavitation, and it causes noise, vibration, loss of head and pitting. To avoid it, the net positive suction head available (NPSHa) must exceed the value the pump requires (NPSHr), given in the manufacturer's curve.

NPSHa = p_atm/(rho g) - suction lift - suction losses - p_vapour/(rho g)

At sea level, water at about 30 C:
  p_atm/(rho g)    = 10.33 m
  p_vapour/(rho g) = about 0.43 m
  suction lift     = 3.0 m
  suction losses   = 0.5 m (assumed)

NPSHa = 10.33 - 3.0 - 0.5 - 0.43 = 6.4 m

Most small domestic pumps need well under this, so the installation is safe. At higher altitudes, with hot water or with long, narrow suction pipes, NPSHa drops quickly. This is why suction pipes are kept short, straight and often one size larger than the delivery pipe.

Changing Speed: The Affinity Laws

For the same centrifugal pump running at a different speed, discharge, head and power scale as shown. They are used when pumps are driven by variable frequency drives.

QuantityProportional toSpeed doubled from 1440 to 2880 rpm
Discharge QN2 times
Head HN^24 times
Power PN^38 times

The cube law for power is why reducing pump speed by just 20 percent can cut power by nearly half (0.8 cubed is 0.512).

Common Mistakes

  • Using only the vertical height and ignoring friction, which leads to undersized pumps in long pipe runs.
  • Mixing Darcy and Fanning friction factors; the Fanning value is one quarter of Darcy.
  • Sizing the motor on hydraulic power without dividing by pump and motor efficiency.
  • Placing the pump too high above the sump so that suction lift exceeds what NPSH allows.
  • Leaving a large safety margin on head, which pushes the pump to run far right of its best efficiency point.

Summary

Total head is static lift plus pipe friction plus fitting losses. Multiply it by rho g Q to get hydraulic power, then divide by efficiencies to size the motor. Always check NPSH on the suction side and use the affinity laws when speed changes. The same method scales from a 1 HP domestic pump to large municipal pumping stations.